Commercial & Industrial ESS Cabinet

100kWh Battery

100kWh Battery for commercial backup, solar storage, peak shaving, and small industrial power projects.

  • ManufacturerSORYQEX Battery Storage Co., Ltd.
  • BrandSORYQEX
  • ModelSORYQEX 100kWh C&I ESS Cabinet

Core Specification

Core Specification Value
Nominal Energy 100kWh
Nominal Voltage 358.4V DC
Battery Chemistry LiFePO4
Rated Capacity 280Ah
Voltage Range 280-408.8V DC
Max. Output Power 50kW
Installation Floor-standing Cabinet

Choose a configuration

The integrated PCS cabinet combines battery storage, PV input and three-phase AC output; confirm grid, PV and backup requirements before quotation.

Datasheet Installation guide PV / AC / CAN / RS485

Key Specifications

Specification Details
Model SORYQEX 100kWh C&I ESS Cabinet
Battery Configuration 1P112S
Rated Capacity 280Ah
Rated Energy 100kWh
Battery Chemistry LiFePO4
Rated Voltage 358.4V DC
Voltage Range 280-408.8V DC
Rated Power 50kW
Rated Charge / Discharge Current 140A / 140A
Rated AC Output 50kW
AC Voltage 3L/N/PE 220/380V, 230/400V, 240/415V
Frequency 50 / 60Hz
Max AC Current 78A
Max PV Input Power 96kW
Max DC Input Voltage 1000V
MPPT Voltage Range 150-850V
Cooling Air Cooling
Fire Protection Aerosol Fire Extinguishing
Detection Temperature / Smoke / Water Leak
Protection Rating IP54
Dimensions 1130 x 1000 x 1600mm
Weight 1.4t
Certification IEC62619 / EN62477-1 / IEC63056

Product Overview

About This C&I Storage Cabinet

  • 100kWh
  • 50kW
  • LiFePO4
  • IP54
  • BESS
  • C&I Cabinet

This cabinet-level C&I BESS is built for commercial sites. The key check is whether the cabinet matches your load list, site voltage, PV design, and backup target.

The SORYQEX 100 kWh LiFePO4 ESS cabinet supports commercial backup, solar self-consumption, and peak-load support for shops, warehouses, cold rooms, offices, small factories, and commercial solar projects.

System Point Project Meaning
Battery side 100 kWh LiFePO4 energy storage cabinet
Power side 50kW rated AC output
Solar side 96kW max PV input, 150-850V MPPT range
Site side Three-phase commercial distribution
Safety side Fire extinguishing with temperature, smoke, and water leak detection

Appliance Compatibility

Size the system from the critical load list, not from nameplate capacity alone.

Load Type Fit / Buyer Note
Office and building backup Suitable - Lighting, network, security, computers
Retail and supermarket loads Suitable - POS, lighting, selected refrigeration
Cold-room support Conditional - Compressor startup must be checked
Pumps and motors Conditional - Needs startup-current review
Commercial HVAC Conditional - Do not size by capacity alone
CNC / production equipment Conditional - Check PCS output and load priority
Whole-factory backup Not direct fit - Needs load separation and engineering review

During backup planning, separate critical loads from non-critical loads. The 50kW rated output is the main continuous-load boundary.

Inverter & Solar Compatibility

Match this C&I cabinet to the site's three-phase voltage, PV array, and backup mode before quotation. The PCS is built in, so solar input and AC output are checked as one system.

Compatibility Item Required Match
AC grid voltage 220/380V, 230/400V, or 240/415V three-phase
PV input Up to 1000V DC, MPPT 150-850V, 96kW max
Rated AC output 50kW continuous
Battery voltage 280-408.8V DC, 358.4V nominal
Operating mode Grid-tied, off-grid, or backup
External inverter Not required. PCS is inside the cabinet

This is a high-voltage cabinet, not a 48V home battery. Do not pair it with a low-voltage hybrid inverter. Before ordering, confirm PV string voltage, three-phase grid voltage, and whether the project is grid-tied, off-grid, or backup-only.

Check System Compatibility

Can It Be Installed and Expanded?

IP54 cabinet for commercial energy storage projects

Installation and protection parameters for this model.

Feature Details
IP Rating IP54
Rated Voltage 358.4V DC
Operating Voltage 280–408.8V DC
Drainage / Installation Ground-mounted outdoor cabinet
Fire Protection Aerosol fire extinguishing

Before installation, check forklift access, floor loading, cabinet clearance, cable routing, ventilation, service space, and distance to the main distribution panel.

Product and Installation Videos

FAQ

What affects project pricing for a 100kWh Battery?

Final price depends on cabinet configuration, PCS / inverter setup, PV input design, fire protection, shipping, installation scope, grid connection requirements, and backup output design.

What drives pack and cabinet cost?

Cost is affected by battery chemistry, cabinet structure, safety system, cooling, certification, communication setup, and whether the project needs integrated solar charging or backup switching.

Is a 100 kWh solar storage cabinet suitable for commercial projects?

Yes, when PV input, AC output, site voltage, and backup loads are matched correctly for the commercial solar design.

How long will backup last?

Runtime depends on the actual load list. A site running 20kW critical loads lasts much longer than a site running 50kW continuous loads, so backup time should be confirmed from the customer's load schedule.

What should buyers provide before quotation?

Send the load list, site voltage, PV system size, backup target, installation location, grid connection type, and whether the project needs critical-load backup, peak shaving, or solar self-consumption.

Chat with SalesWhatsApp